VolnewmerRadiofrequency heat delivered broadly,while the skin surface stays cool.

Volnewmer is a 6.78 MHz monopolar radiofrequency device made by CLASSYS. We first check your skin condition, then decide whether the procedure is appropriate and which areas to treat.

Last updated Medical review in progress

012345mmEpidermisDermisSubcutaneous fatSMAS (fascia)MuscleElectrode tipContact cooling protects epidermisHeat from tissue resistance (broad)To return pad on the body →
Simplified cross-section of facial skin · actual thickness varies by area and person

At a glance

Volnewmer passes radiofrequency current between an electrode tip and a return pad attached to the body, and the heat generated as tissue resists the current is delivered relatively broadly, centred on the dermis. During treatment, water-cooled contact cooling protects the epidermis. Results and how long they last vary between individuals, and it is not a substitute for surgical lifting.

How it works

Monopolar RF uses a single electrode in contact with the treatment area, with the current returning through a return pad attached elsewhere on the body. As the current passes through tissue, resistance generates heat, and the device is designed so that this heat acts on collagen in the dermis.

According to the manufacturer, Volnewmer protects the epidermis with continuous water-cooled contact cooling during treatment and checks skin contact (impedance) before delivering energy. Even with these features it is a heat-based procedure, so settings matched to your skin and the practitioner's judgement are important.

Device information

Information published by the manufacturer. The tips and settings used at MODNI are explained at the consultation.

Manufacturer
CLASSYS, Republic of Korea
Energy
Radiofrequency 6.78 MHz, monopolar
Cooling
Continuous water-cooled contact cooling
Safety features
Impedance check before energy delivery; electrode edge set inside the tip
Tips (manufacturer's range)
I tip for delicate areas such as around the eyes, F tip for contours, V tip for the face, S tip for body areas
Approval
Medical device approved by the Korean Ministry of Food and Drug Safety (MFDS), as stated by the manufacturer

Source: CLASSYS. VOLNEWMER product information (manufacturer's published material).

Who it suits

Good reasons to consult
Overall loss of skin firmness, concern about texture or fine lines, or wanting a procedure with little recovery time
Needs checking first
Recent fillers, thread lifts or other procedures; very sensitive skin or marked redness (flushing)
Not performed or postponed
An implanted electronic device such as a pacemaker, a metal implant in the treatment area, pregnancy, or inflammation, wounds or an active skin condition in the treatment area

The procedure

  1. 01

    Consultation and skin check

    We check your skin condition, areas of concern and past procedures, and decide the treatment area.

  2. 02

    Preparation

    After cleansing, the treatment area is marked and a return pad is attached to your body.

  3. 03

    Treatment

    The cooled tip is placed on the skin and each area is treated in turn. If the heat feels strong, please tell us right away.

  4. 04

    Soothing and aftercare advice

    We check your skin and explain how to care for it on the day.

Precautions and possible side effects

  • You may feel warmth or heat during treatment.
  • After treatment there may be temporary redness, swelling or warmth, which usually settles within a short time.
  • Rarely, burns, blisters or temporary reduced sensation can occur. If symptoms persist, please contact us right away.
  • Results and how long they last vary between individuals, and it is not a substitute for surgical lifting.

Aftercare

  1. 1On the day of treatment, avoid saunas, strenuous exercise and alcohol.
  2. 2Apply sunscreen thoroughly and keep your skin well moisturized.
  3. 3Take a break from harsh exfoliation or scrubs for a few days.
  4. 4If redness or swelling lasts a long time, or blisters or severe pain develop, please contact us right away.

Frequently asked questions

Does it hurt?

Treatment is performed with cooling, but you may still feel warmth or heat. How strongly you feel it depends on the area and the individual, and we adjust the intensity during treatment.

How many shots will I have?

We do not set fixed shot-count packages in advance. We explain this at the consultation after checking your skin condition and treatment areas.

Can I have it together with Shurink Universe?

Depending on your skin condition, both procedures are sometimes planned together. The order and interval are decided after the consultation.

References

  1. CLASSYS. VOLNEWMER product information (manufacturer's published material). classys.com
  2. Weiss RA. Noninvasive radio frequency for skin tightening and body contouring. Semin Cutan Med Surg. 2013;32(1):9–17.

Related pages

오경석 대표원장

Your doctor

Director Oh Kyung-seok, KMD

Graduate, College of Korean Medicine, Gachon University · The director personally provides care, from assessment through follow-up.

Last updated Medical review in progress

About the director

First, we check whether Volnewmer is right for you.

After checking your skin, we explain whether the procedure is suitable, the treatment range and the degree of change that can be expected.

+82-2-6205-1236 · 2F, K Building, 626 Samseong-ro, Gangnam-gu, Seoul, Republic of Korea · Location & hours